Extrusion & Post 12 görüntüleme

PVDF Film Processing and Pore Control

Sorun Belirtisi
【Problem phenomenon】In the extrusion and stretching of PVDF water treatment membranes and battery separators, porosity and pore size distribution fail to meet requirements
Neden Analizi
The membrane pore structure depends on the casting solution formulation, coagulation bath conditions, or stretching process parameters, and temperature and humidity fluctuations cause pore size drift; extrusion-grade PVDF used for filtration, separation, and separators has extremely high requirements for pore structure consistency
Çözüm
Lock the coagulation bath temperature and humidity or the stretching ratio and temperature according to the membrane process route; online monitor thickness and air permeability for feedback adjustment; incorporate raw material batch molecular weight differences into process fine-tuning
Temel Çıkarım
The soul of PVDF membranes lies in the pore structure; process parameters must be controlled in an online closed loop; After confirming effectiveness, fix the parameters and practices into the work instruction to prevent recurrence