Production & Quality 12 görüntüleme

EVA fatigue resistance is poor

Sorun Belirtisi
EVA product fatigue life <10⁴ cycles, below the 10⁵ cycle requirement
Neden Analizi
EVA elastic recovery insufficient, accumulating plastic deformation each cycle; crosslinking degree too low with fast fatigue crack propagation
Çözüm
1) Increase crosslinking degree to improve recovery and reduce accumulated deformation; 2) Select high molecular weight grade to raise the fatigue threshold; 3) Product design to reduce stress concentration
Temel Çıkarım
Poor fatigue resistance is caused by insufficient recovery and fast crack propagation; increasing crosslinking is key