Material Analysis
5 görüntüleme
Poor chemical resistance of PU
Sorun Belirtisi
After soaking in acid-alkali solvents, PU product mechanical properties decrease >30%
Neden Analizi
PU has high affinity to specific chemicals, being attacked and swollen; PU molecular chains attacked by chemicals and broken
Çözüm
1) Select chemical-resistant grade; 2) Slight crosslinking to reduce swelling; 3) Surface coating protection of products; 4) Add chemical stabilizer
Temel Çıkarım
Poor chemical resistance is caused by PU chemical affinity; selecting chemical-resistant grade and coating are key