Processing Machinery 6 görüntüleme

Incomplete cleaning during material/color change causes mixing or color difference

Sorun Belirtisi
Incomplete cleaning during material/color change causes mixing or color difference
Neden Analizi
Incomplete barrel cleaning, residual old material Insufficient screw cleaning time Poor compatibility between new and old materials, poor interface Insufficient purging amount during color change, color difference Improper cleaning agent selection, residual contamination
Çözüm
Fully clean the barrel and screw Extend cleaning time to ensure thoroughness Consider compatibility of new and old materials Increase purging amount to ensure color consistency Select suitable cleaning agents
Temel Çıkarım
Material/color change requires full cleaning and purging