CEF processing temperature fluctuation

Sorun Belirtisi
The temperature fluctuates ±5-8°C during CEF processing, exceeding the ±2°C control accuracy
Neden Analizi
The PID parameters of the temperature control system are improper; the heating ring is aging and the power is uneven; the thermocouple position is improper and the measurement is deviated
Çözüm
1) Readjust the PID parameters; 2) Replace the aging heating ring; 3) Adjust the thermocouple position to the center of the melt pool
Temel Çıkarım
Temperature fluctuation is caused by improper temperature control system; PID adjustment and heating ring replacement are the key