Material Analysis
12 görüntüleme
CEF flexural modulus low
Sorun Belirtisi
The flexural modulus of the CEF product is <20% of the design value
Neden Analizi
CEF is soft and has low modulus; the filler addition is insufficient or the interface is poor and does not play a reinforcing role; the crystallinity is low
Çözüm
1) Add 10-15wt% rigid filler to increase the modulus; 2) Nucleating agent to increase the crystallinity; 3) Select high-modulus grades
Temel Çıkarım
Low flexural modulus is caused by the softness of the material and insufficient filler; adding rigid fillers is the key
Bu faydalı oldu mu?
0 kişi bunu faydalı buldu