Molding Process 8 görüntüleme

DSTDP processing temperature fluctuation

Sorun Belirtisi
During DSTDP processing, temperature fluctuates ±5-8°C, exceeding the ±2°C control accuracy
Neden Analizi
Temperature control system PID parameters improper; heating band aged, power uneven; thermocouple position improper, measurement deviation
Çözüm
1) Re-tune PID parameters; 2) replace aged heating bands; 3) adjust thermocouple position to the center of the melt pool
Temel Çıkarım
Temperature fluctuation is caused by improper temperature control system; PID tuning and heating band replacement are key