Molding Process 8 görüntüleme

MP processing temperature fluctuation

Sorun Belirtisi
during MP processing temperature fluctuates ±5-8°C, exceeding the ±2°C control accuracy
Neden Analizi
temperature control system PID parameters improper; heater bands aged, power uneven; thermocouple position improper, measurement deviation
Çözüm
1) retune PID parameters; 2) replace aged heater bands; 3) adjust thermocouple position to the melt pool center
Temel Çıkarım
temperature fluctuation is caused by an improper temperature control system; PID tuning and heater band replacement are key
MP temperature fluctuation PID tuning heater band thermocouple