Material Drying
5 görüntüleme
Control of transparency abnormality in PEOX calendering medical products
Sorun Belirtisi
During PEOX calendering production of medical products, the problem of unstable transparency occurs.
Neden Analizi
Mainly due to the processing temperature deviating from the window +65-95°C, moisture content >0.5% exceeding the standard, and insufficient cooling.
Çözüm
Strictly control the temperature within the recommended range, fully dry the material to moisture content <0.1%, and shorten the residence time.
Temel Çıkarım
PEOX processing requires precise control of the three elements of temperature, humidity, and residence time.