Injection Molding 5 görüntüleme

Severe Anisotropy in Thin-Wall Filling in LCP '2079851475616104452

Sorun Belirtisi
The properties of LCP products differ greatly between the flow direction and the perpendicular direction (shrinkage rate 0-0.2% in the flow direction, 0.5-1.0% in the perpendicular direction), and the products warp and deform.
Neden Analizi
LCP molecular chains are highly oriented in the flow direction, forming a skin-core structure, resulting in strong mechanical and shrinkage anisotropy.
Çözüm
Optimize the gate position so that the flow direction matches the stress direction; use multiple gates to reduce orientation; the mold design considers anisotropic shrinkage compensation.
Temel Çıkarım
The anisotropy of LCP is a double-edged sword: utilizing orientation can obtain high strength, but it also brings shrinkage and warpage challenges.
LCPanisotropyshrinkageskin-core structuregate