Molding Process 8 görüntüleme

POE processing temperature fluctuation

Sorun Belirtisi
POE processing temperature fluctuates ±5-8°C, exceeding ±2°C control accuracy
Neden Analizi
Temperature control system PID parameters improper; heating band aged, power uneven; thermocouple position improper, measurement deviation
Çözüm
1) Re-tune PID parameters; 2) Replace aged heating bands; 3) Adjust thermocouple position to the center of the melt pool
Temel Çıkarım
Temperature fluctuation is caused by improper temperature control system; PID tuning and heating band replacement are key
POEtemperature fluctuationPID tuningheating bandthermocouple