Material Analysis
5 görüntüleme
Uneven pore size of hollow fiber membranes
Sorun Belirtisi
The membrane fiber pore size distribution is wide and the filtration accuracy is poor
Neden Analizi
The casting solution composition is not uniform and the phase inversion conditions fluctuate
Çözüm
Polymer concentration 12-18%, coagulation bath 20-40C, constant temperature and humidity
Temel Çıkarım
Membrane pore size uniformity is the key to membrane performance
Bu faydalı oldu mu?
0 kişi bunu faydalı buldu