Processing Machinery
5 görüntüleme
Sizing device failure of random copolymer polypropylene pipe special material extruder (Variant: strengthened measures)
Sorun Belirtisi
After sizing, the dimensional deviation of the pipe or profile is large, and the roundness or cross-sectional shape is unqualified.
Sizing device failure leads to reduced dimensional accuracy of the product.
In particular, extra attention is needed on the original basis, this problem is more prominent and needs key attention.
Neden Analizi
(1)The vacuum degree of the vacuum sizing sleeve is insufficient or unevenly distributed
(2)The sizing sleeve is worn, and the inner diameter becomes larger
(3)The cooling water flow is insufficient or the temperature is too high
(4)The sizing sleeve is not concentric with the die
(5)There is scale or impurities on the inner wall of the sizing sleeve
(6)On the original basis, extra attention is needed: process parameter fluctuations or equipment status changes have aggravated this problem
Çözüm
(1)Check the vacuum pump and pipelines to ensure that the vacuum degree is stable at 0.04-0.08MPa
(2)Check the wear of the sizing sleeve, and replace it if it exceeds the tolerance
(3)Increase the cooling water flow and control the water temperature at 15-25°C
(4)Adjust the concentricity of the sizing sleeve and the die
(5)Regularly clean the inner wall of the sizing sleeve to remove scale
(6)And strengthen process monitoring; on the original basis, extra attention is needed, with special attention to parameter stability
Temel Çıkarım
Sizing device failure needs to be solved from three aspects: vacuum system, cooling system, and mold accuracy.
In different production scenarios, targeted preventive measures need to be taken.