Injection Molding 12 görüntüleme

Mold Corrosion Caused by Poor Cooling Water Quality During PBT '2079851475616104452

Sorun Belirtisi
The mold cooling water channels are rusted or corroded, and the cooling efficiency decreases.
Neden Analizi
The cooling water quality is poor (improper pH value, containing corrosive ions); the mold material is not corrosion-resistant; it is used for a long time without maintenance.
Çözüm
Use treated cooling water (neutral pH, deionized); use stainless steel water channels or anti-rust coatings; flush regularly.
Temel Çıkarım
PBT mold cooling water management extends mold life.