Injection Molding 12 görüntüleme

Insufficient Pressure Supply of PBT '2079851475616104452 Hydraulic System

Sorun Belirtisi
During the injection or holding stage, the hydraulic system pressure cannot reach the set value.
Neden Analizi
The hydraulic pump is worn and the output is insufficient; the proportional valve is stuck and responds slowly; the system leaks; the hydraulic oil is insufficient or contaminated.
Çözüm
Check and maintain the hydraulic pump and valve block; replace the hydraulic oil and keep it clean; check the pipeline sealing.
Temel Çıkarım
Insufficient PBT injection pressure directly affects filling and holding.