12 görüntüleme
Screw Wear of PC '2079851475616104452 Machine
Sorun Belirtisi
When processing glass fiber reinforced PC, the screw and barrel wear severely.
Neden Analizi
Glass fiber has high hardness and is strongly abrasive to the screw, and the screw material is not wear-resistant.
Çözüm
Use bimetallic or tungsten carbide coated screws; reduce the glass fiber content.
Temel Çıkarım
PC reinforced materials are a test of equipment wear.