Sorun Belirtisi
After adding thermally conductive fillers (graphite, boron nitride) to PET, melt viscosity increases sharply, processing difficult, surface rough.
Neden Analizi
High filling amount (>30%) causes sharp fluidity decline, poor filler-matrix compatibility produces interfacial friction, uneven filler dispersion.
Çözüm
Use coupling agents to improve the interface; optimize screw configuration to improve dispersion; appropriately increase processing temperature; control filling amount ≤50%.
Temel Çıkarım
PET thermally conductive composite processability depends on filler selection and interface treatment.