Injection Molding
5 görüntüleme
Nozzle drooling
Sorun Belirtisi
Melt continuously flows out of the injection machine nozzle during mold opening, affecting metering accuracy
Neden Analizi
Melt viscosity is too low; nozzle temperature is set too high; the proportion of low-viscosity components in the blend is on the high side
Çözüm
Appropriately reduce nozzle temperature by 10-20°C; use a self-locking nozzle; adjust the alloy ratio to increase overall melt viscosity
Temel Çıkarım
Nozzle drooling affects product weight consistency and production stability
Bu faydalı oldu mu?
0 kişi bunu faydalı buldu
Geri bildiriminiz için teşekkürler!