Processing Machinery 5 görüntüleme

Severe screw corrosion during processing of flame retardant blend systems

Sorun Belirtisi
Corrosion pits appear on the screw and barrel of halogen-containing flame retardant systems
Neden Analizi
Halogen-containing flame retardants decompose at processing temperature, releasing HX (hydrogen halide) acidic gas; the acidic gas reacts with metal at high temperature
Çözüm
Switch to halogen-free flame retardant systems (phosphorus-based, nitrogen-based, intumescent); use bimetallic corrosion-resistant screws and barrels; add acid absorbers (such as hydrotalcite)
Temel Çıkarım
The compatibility of the flame retardant system with equipment materials is the prerequisite for long-term stable production