Extrusion & Post 6 مشاهدة

Substrate Sagging After Coating and Before Curing

ظاهرة المشكلة
After curing, the coating has insufficient hardness, a tacky surface, poor solvent resistance or decreased adhesion, and an obvious indentation can be seen when pressed with a fingernail. Incomplete curing means that the reactive groups in the coating have not fully crosslinked into a three-dimensional network structure, and residual low-molecular-weight components cause the performance to fall below standard. An incompletely cured coating continues to post-cure during subsequent use, and its performance changes unstably over time.
تحليل الأسباب
1. Comprehensive factor: the coating viscosity is too low or the coating is too thick. 2. Comprehensive factor: long residence time before curing. 3. Material/formulation factor: the substrate temperature is too high, causing the coating viscosity to decrease.
الحل
1. Process parameter optimization and adjustment: appropriately increase the thixotropy or viscosity of the coating liquid. 2. Mold/tooling improvement and maintenance: reduce the coating thickness. 3. Equipment inspection and system maintenance: shorten the time and distance from coating to entering the oven. 4. Systematic troubleshooting method: troubleshooting of coating problems follows the sequence of "substrate → coating liquid → coating head → curing → environment". First check the substrate surface tension (corona treatment effect) and cleanliness, then check the viscosity, solid content and degassing state of the coating liquid, next check the coating head gap and cleanliness, further verify the curing temperature and time, and finally evaluate the influence of ambient temperature, humidity and cleanliness. 5. Preventive management: establish standardized process parameter cards and quality control limits for each mold/product, and regularly conduct process capability index (CPK) evaluations. For recurring problems, use fishbone diagrams or the 5Why analysis method to trace the root cause, and solidify the countermeasures as PFMEA control points. Establish a regular equipment maintenance system, and implement life management for key tooling such as dies/spinnerets/calender rolls/coating heads.
الخلاصة الأساسية
The essence of incomplete curing is that the crosslinking reaction has not reached the designed conversion rate. The core of the solution is the precise matching of the three elements "temperature + time + formulation": ensure the curing temperature and time are within the recommended window of the coating liquid system, check the curing agent ratio and validity period, and for UV curing, regularly test the lamp light intensity and replace it in time.