Material Drying
6 مشاهدة
PA12 Transparent Grade Processing
ظاهرة المشكلة
【Problem phenomenon】Transparent PA12 (TR90 type) products had uneven transparency, with flow marks and specks
تحليل الأسباب
Transparent grade PA12 is more sensitive to drying and melt cleanliness: moisture and impurities directly manifest as visible defects; keeping the melt stable within the 230-250℃ processing temperature window is the prerequisite for transparency
الحل
Strictly execute transparent grade drying at 90-100℃×4-10h; do not exceed the melt temperature limit of 230-250℃; make mold temperature and cooling uniform to prevent optical distortion; prohibit or strictly limit regrind
الخلاصة الأساسية
The cleanliness of transparent PA12 is its transparency; both drying and temperature are strictly controlled; after confirming effectiveness, solidify the parameters and practices into the work instruction to prevent recurrence; include this case in the defect archive as a reference for troubleshooting similar problems in the future
هل كان هذا مفيدًا؟
0 شخص وجدوا هذا مفيدًا