القائمة
المواد الآلات
رؤى
مقالات مقاطع فيديو المشاكل والحلول
About
عن Chembull شركاء الإعلام
اتصل بنا
اللغة
EnglishالعربيةPortuguêsEspañolDeutschTürkçe한국어
العودة إلى المشاكل والحلول
Material Analysis 13 مشاهدة

Inspection Dispute of PEEK Aerospace Parts

ظاهرة المشكلة
The supplier and buyer of PEEK aerospace parts have inconsistent crystallinity determination results — the supplier's self-inspection passes while the customer's re-inspection fails — and delivery falls into dispute.
تحليل الأسباب
Inconsistent sampling positions, heating rates, and interpretation standards of DSC testing lead to divergent results; the crystallinity of different parts of the product itself has gradients, and single-point sampling is insufficiently representative.
الحل
①Both parties agree on the DSC test standard method and sampling position map; ②Take multi-point samples at critical cross-sections and judge by the worst value; ③Use third-party laboratory arbitration testing; ④Write the test specification into the technical agreement.
الخلاصة الأساسية
For PEEK crystallinity determination, the test standard must first be unified before discussing qualification; multi-point sampling reflects the true gradient; pre-agreement in the technical agreement can avoid delivery disputes.
PEEK;aerospace;crystallinity;DSC;inspection standard;dispute

هل كان هذا مفيدًا؟

0 شخص وجدوا هذا مفيدًا

ChemAI