القائمة
المواد الآلات
رؤى
مقالات مقاطع فيديو المشاكل والحلول
About
عن Chembull شركاء الإعلام
اتصل بنا
اللغة
EnglishالعربيةPortuguêsEspañolDeutschTürkçe한국어
العودة إلى المشاكل والحلول
Production & Quality 6 مشاهدة

PEI Chlorinated Solvent Corrosion

ظاهرة المشكلة
After PEI products contact chlorinated polar solvents, surface erosion and stress cracking occur; failures happen in medical cleaning scenarios.
تحليل الأسباب
PEI is easily corroded by polar chlorinated solvents; certain solvent erosion in hospital environments manifests as environmental stress cracking; areas with high internal stress crack faster; chemical resistance has clear boundaries.
الحل
①Avoid contact with chlorinated polar solvents; ②perform compatibility verification according to the actual contact medium; ③low-stress molding; ④select compatible disinfectants for medical cleaning.; after adjustment, continuously sample to verify the effect, and resume mass production after confirming stability
الخلاصة الأساسية
The chlorinated solvent taboo of PEI chemical resistance is a clear knowledge point; solvent management in medical scenarios is a quality link; compatibility verification cannot be omitted.; after confirming effectiveness, fix the parameters and practices into the work instruction to prevent recurrence
PEI;chlorinated solvent;corrosion;stress cracking;medical;compatibility

هل كان هذا مفيدًا؟

0 شخص وجدوا هذا مفيدًا

ChemAI