Extrusion & Post
13 مشاهدة
PET Bottle Unreasonable Heating Temperature Gradient
ظاهرة المشكلة
The whole batch of bottles shows whitening or insufficient stretching at fixed positions, and changing preforms does not solve it.
تحليل الأسباب
Unreasonable infrared lamp power distribution, uneven heating distance, too fast temperature rise, and insufficient ventilation and heat dissipation make the preform surface zone temperature difference exceed 15℃ (beyond process tolerance).
الحل
①Calibrate the lamp zone power gradient according to the bottle type (low at the neck, high at the body, moderate at the bottom); ②calibrate the heating distance; ③check the ventilation fan; ④use temperature measurement means to verify the preform surface temperature field.
الخلاصة الأساسية
The lamp zone gradient is the core parameter of the blow '2079851475616104453.
هل كان هذا مفيدًا؟
0 شخص وجدوا هذا مفيدًا