Injection Molding 7 مشاهدة

Unbalanced multi-cavity filling in EEA injection

ظاهرة المشكلة
EEA injection 8-cavity mold, filling amount difference between cavities ±15%, some cavities short shot, some flash
تحليل الأسباب
Unbalanced runner design, runner length and resistance of each cavity inconsistent; gate size of each cavity inconsistent
الحل
1) Adopt balanced runner design to ensure equal length and resistance of each cavity runner; 2) Gate size of each cavity precisely consistent ±0.01mm; 3) Reduce injection speed to reduce the influence of resistance difference; 4) Use mold flow analysis software to optimize runner design
الخلاصة الأساسية
Unbalanced multi-cavity filling is caused by runner design; balanced runner and mold flow analysis are the key
EEA injectionmulti-cavity balancerunner designgate sizemold flow analysis