Injection Molding 7 مشاهدة

Unbalanced filling of multi-cavity in PU '2079851475616104452

ظاهرة المشكلة
In PU '2079851475616104452 with an 8-cavity mold, the filling amount of each cavity differs by ±15%, some cavities have short shots and some have flash
تحليل الأسباب
Unbalanced runner design, the runner length and resistance of each cavity are inconsistent; the gate sizes of each cavity are inconsistent
الحل
1) Adopt balanced runner design to ensure each cavity runner is equal in length and resistance; 2) Gate sizes of each cavity precisely consistent at ±0.01mm; 3) Reduce injection speed to reduce the influence of resistance differences; 4) Use mold flow analysis software to optimize runner design
الخلاصة الأساسية
Multi-cavity filling imbalance is caused by runner design; balanced runners and mold flow analysis are key
PU injection multi-cavity balance runner design gate size mold flow analysis