القائمة
المواد الآلات
رؤى
مقالات مقاطع فيديو المشاكل والحلول
About
عن Chembull شركاء الإعلام
اتصل بنا
اللغة
EnglishالعربيةPortuguêsEspañolDeutschTürkçe한국어
العودة إلى المشاكل والحلول
Injection Molding 5 مشاهدة

Front zone temperature directly affects the temperature and flowability of the melt entering the cavity

ظاهرة المشكلة
Front zone temperature directly affects the temperature and flowability of the melt entering the cavity
تحليل الأسباب
Front zone temperature too high, exceeding the 170-230°C upper limit, large degradation risk Front zone temperature on the low side, insufficient melt flowability Front zone temperature fluctuation, unstable injection Too large temperature difference between front zone and nozzle, cold slug risk Front zone temperature setting did not consider cellulose acetate butyrate thermal stability
الحل
Set front zone temperature near the 170-230°C upper limit but not exceeding it Ensure front zone temperature stability, fluctuation ≤2°C Nozzle temperature 5-10°C lower than front zone to prevent cold slug Carefully set front zone temperature according to cellulose acetate butyrate thermal stability Avoid front zone temperature too high causing degradation
الخلاصة الأساسية
Front zone temperature needs stable control near the recommended upper limit
front zone temperaturemelt temperaturethermal stability