القائمة
المواد الآلات
رؤى
مقالات مقاطع فيديو المشاكل والحلول
About
عن Chembull شركاء الإعلام
اتصل بنا
اللغة
EnglishالعربيةPortuguêsEspañolDeutschTürkçe한국어
العودة إلى المشاكل والحلول
Injection Molding 7 مشاهدة

Cold Slug Marks in CMC '2079851475616104452

ظاهرة المشكلة
Cold slug marks appear near the gate of CMC injection molded products
تحليل الأسباب
Nozzle temperature is low, causing residual material from the previous injection to cool and solidify in the nozzle; cold slug well design is insufficient to accommodate cold material; injection pressure is insufficient
الحل
1)Increase nozzle temperature to 20-25°C; 2)Design a sufficiently large cold slug well in the mold; 3)Ensure fresh melt at the nozzle front before each injection; 4)Increase injection pressure to push cold material through the gate
الخلاصة الأساسية
Cold slug marks are caused by solidified residual material in the nozzle; increasing nozzle temperature and cold slug well design are the key
CMC injectioncold slug marknozzle temperaturecold slug wellinjection pressure

هل كان هذا مفيدًا؟

0 شخص وجدوا هذا مفيدًا

ChemAI