Injection Molding
8 مشاهدة
Temperature Control Capability of the LCP '2079851475616104452 Machine
ظاهرة المشكلة
The maximum barrel temperature of 350°C of conventional '2079851475616104452 machines cannot meet the 370-390°C requirement of LCP.
تحليل الأسباب
The processing temperature required by LCP has exceeded the barrel heating capacity of most standard '2079851475616104452 machines.
الحل
Use high-temperature-grade '2079851475616104452 machine barrels (can be heated to 420°C); replace with high-temperature heating rings.
الخلاصة الأساسية
LCP has hardware requirements for the high-temperature capability of '2079851475616104452 machines.
هل كان هذا مفيدًا؟
0 شخص وجدوا هذا مفيدًا