Menü
Materialien Maschinen
Einblicke
Artikel Videos Problem & Lösung
About
Über Chembull Medienpartner
Kontaktieren Sie uns
Sprache
EnglishالعربيةPortuguêsEspañolDeutschTürkçe한국어
Zurück zu Problem & Lösung
Molds & Tooling 6 Aufrufe

Mold cavity scoring

Problembeschreibung
Scoring marks appear on the cavity surface affecting the product surface. When this defect appears in products of Process No. 4, it is usually related to a specific process parameter range or equipment state. If it continues to appear, it will directly affect the product qualification rate and production rhythm, increasing material loss and rework costs. Timely diagnosis and elimination is a basic requirement for ensuring stable production.
Ursachenanalyse
1. Mold design factors: friction between the product and the cavity during demolding, insufficient mold hardness, foreign matter in the cavity, insufficient draft angle. 2. Runner and gate design factor: In transfer molding, the material needs to enter the cavity through runners and gates; the runner length, cross-sectional shape and gate size directly affect pressure loss, fiber breakage and filling balance, and unreasonable design is the root of many quality problems. 3. Feeding factor: The volume of the feeding chamber, the feeding amount and the preheating state of the material directly determine the transfer pressure and filling effect, and are key variables unique to transfer molding.
Lösung
1. Process parameter optimization and adjustment: increase the draft angle, use high-hardness mold steel, clean the cavity, add release agent. 2. Systematic troubleshooting method: Troubleshooting of transfer molding problems follows the order of 'runner -> feeding -> parameters -> mold'. First check whether the runners and gates are blocked or worn, then verify the feeding amount and material preheating, then adjust the transfer pressure and speed, and finally check the mold venting and temperature uniformity. 3. Preventive management: Establish standardized process parameter cards and quality control limits for each set of mold/product, and regularly conduct process capability index (CPK) evaluations. For recurring problems, use fishbone diagrams or 5Why analysis to trace the root cause, and solidify the countermeasures as PFMEA control points.
Wichtigste Erkenntnis
This problem is a typical manifestation of mold cavity scoring in transfer molding; the core of the solution lies in the rational design of the runner and gate system, the effective transmission of transfer pressure, and the uniform control of mold temperature. It is recommended to start troubleshooting from the runner system and transfer parameters.
draft anglemold polishingholding pressurecooling timerelease agent

War das hilfreich?

0 Personen fanden dies hilfreich

ChemAI