Menü
Materialien Maschinen
Einblicke
Artikel Videos Problem & Lösung
About
Über Chembull Medienpartner
Kontaktieren Sie uns
Sprache
EnglishالعربيةPortuguêsEspañolDeutschTürkçe한국어
Zurück zu Problem & Lösung
Extrusion & Post 3 Aufrufe

Coating Leaking to the Back Side When Coating a Mesh Substrate

Problembeschreibung
The coating liquid passes through the mesh openings and appears on the back side of the substrate and cures. When this defect appears in coating-formed products, it is usually closely related to the coating head precision, the rheological properties of the coating liquid, the substrate surface condition, or the curing process conditions. The distribution characteristics of coating defects (transverse/longitudinal/random) provide important clues for diagnosing coating head and curing system problems. Continuous occurrence will cause the functional performance of the coating to fall below standard, and coordinated troubleshooting is required from three aspects: coating liquid formulation, coating equipment, and curing process.
Ursachenanalyse
1. Material/formulation factor: the coating liquid viscosity is too low and it does not cure before penetration. 2. Comprehensive factor: the coating amount is too large. 3. Material/formulation factor: the substrate mesh openings and fabric pores are large.
Lösung
1. Process parameter optimization and adjustment: increase the coating liquid viscosity to limit its penetration. 2. Mold/tooling improvement and maintenance: reduce the coating amount. 3. Equipment inspection and system maintenance: first perform a pre-sealing primer treatment on the substrate. 4. Systematic troubleshooting method: troubleshooting of coating problems follows the sequence of "substrate → coating liquid → coating head → curing → environment". First check the substrate surface tension (corona treatment effect) and cleanliness, then check the viscosity, solid content and degassing state of the coating liquid, next check the coating head gap and cleanliness, further verify the curing temperature and time, and finally evaluate the influence of ambient temperature, humidity and cleanliness. 5. Preventive management: establish standardized process parameter cards and quality control limits for each mold/product, and regularly conduct process capability index (CPK) evaluations. For recurring problems, use fishbone diagrams or the 5Why analysis method to trace the root cause, and solidify the countermeasures as PFMEA control points. Establish a regular equipment maintenance system, and implement life management for key tooling such as dies/spinnerets/calender rolls/coating heads.
Wichtigste Erkenntnis
This problem is a typical manifestation of coating leaking to the back side when coating a mesh substrate in coating forming. The core of the solution lies in ensuring the substrate surface condition, optimizing the rheological properties of the coating liquid, and precisely controlling the curing process conditions. It is recommended to start from the two aspects of substrate and coating liquid, and gradually troubleshoot to the coating equipment and curing system.
incomplete curingcuring temperaturecuring timecuring agent ratioUV lamp

War das hilfreich?

0 Personen fanden dies hilfreich

ChemAI