Menü
Materialien Maschinen
Einblicke
Artikel Videos Problem & Lösung
About
Über Chembull Medienpartner
Kontaktieren Sie uns
Sprache
EnglishالعربيةPortuguêsEspañolDeutschTürkçe한국어
Zurück zu Problem & Lösung
Processing Machinery 2 Aufrufe

PA12 Product Dimensional Stability

Problembeschreibung
Dimensions change with the environment.
Ursachenanalyse
PA12 has low water absorption (0.25% saturation) and better dimensional stability than PA6/PA66; but it is still affected by temperature and humidity.; During on-site troubleshooting, verify item by item according to this mechanism to avoid blindly adjusting the machine based solely on experience
Lösung
①Evaluate water absorption impact according to application; ②conditioning to stabilize dimensions; ③control environment; ④test after aging.; After adjustment, continuously sample to verify the effect, and resume mass production only after confirming stability
Wichtigste Erkenntnis
PA12 dimensional stability is its advantage over PA6/PA66; low water absorption is the core value.; After confirming effectiveness, solidify the parameters and practices into the work instruction to prevent recurrence
PA12;dimensional stability;water absorption;conditioning;environment;aging

War das hilfreich?

0 Personen fanden dies hilfreich