Processing Machinery
7 visualizaciones
PA12 Product Dimensional Stability
Fenómeno del problema
Dimensions change with the environment.
Análisis de la causa
PA12 has low water absorption (0.25% saturation) and better dimensional stability than PA6/PA66; but it is still affected by temperature and humidity.; During on-site troubleshooting, verify item by item according to this mechanism to avoid blindly adjusting the machine based solely on experience
Solución
①Evaluate water absorption impact according to application; ②conditioning to stabilize dimensions; ③control environment; ④test after aging.; After adjustment, continuously sample to verify the effect, and resume mass production only after confirming stability
Conclusión clave
PA12 dimensional stability is its advantage over PA6/PA66; low water absorption is the core value.; After confirming effectiveness, solidify the parameters and practices into the work instruction to prevent recurrence
¿Le ha resultado útil?
0 personas encontraron esto útil
¡Gracias por sus comentarios!