Molds & Tooling 6 Aufrufe

PA6 Glass Fiber Reinforced Warpage

Problembeschreibung
GF-PA6 products warped in a fixed direction, cooling adjustment was ineffective, and repeatability was strong.
Ursachenanalyse
Glass fiber orientation makes flow-direction shrinkage far lower than transverse; the gate determines orientation; GF-PA6 warpage is typical fiber-orientation-type warpage; during on-site troubleshooting, verify item by item according to this mechanism, and avoid blindly adjusting the machine based only on experience.
Lösung
①Adjust the gate position;②use Moldflow etc. for fiber orientation and warpage analysis;③balance holding pressure and cooling;④verify whether the fiber content and grade meet requirements;⑤evaluate low-warpage grades.
Wichtigste Erkenntnis
GF-PA6 warpage = 'fiber orientation': the gate is the switch; orientation-type warpage has a fixed direction, hard pressing by cooling is ineffective, and adjustment must be made from the source of gate and orientation.