Injection Molding
5 Aufrufe
PET Injection Preform Gate Crystallization (Whitening)
Problembeschreibung
Whitening around the preform gate, and the bottom easily cracks during blowing.
Ursachenanalyse
Gate zone shear heat + uneven cooling cause local crystallization; crystallized preforms cannot be oriented during blowing, and the bottom strength is poor.
Lösung
①Optimize gate temperature and cooling; ②reduce gate zone shear; ③check hot runner gate temperature control; ④reject whitened preforms.
Wichtigste Erkenntnis
Gate whitening = local crystallization, a hidden danger at the bottom.
War das hilfreich?
0 Personen fanden dies hilfreich