Injection Molding
3 visualizaciones
PET Injection Preform Gate Crystallization (Whitening)
Fenómeno del problema
Whitening around the preform gate, and the bottom easily cracks during blowing.
Análisis de la causa
Gate zone shear heat + uneven cooling cause local crystallization; crystallized preforms cannot be oriented during blowing, and the bottom strength is poor.
Solución
①Optimize gate temperature and cooling; ②reduce gate zone shear; ③check hot runner gate temperature control; ④reject whitened preforms.
Conclusión clave
Gate whitening = local crystallization, a hidden danger at the bottom.
¿Le ha resultado útil?
0 personas encontraron esto útil
¡Gracias por sus comentarios!