Material Analysis 10 Aufrufe

PLA Melt Temperature 170-230℃

Problembeschreibung
Low melt temperature causes poor plasticization; high temperature causes a sharp viscosity drop, product embrittlement and discoloration
Ursachenanalyse
PLA melting point is 155-185℃, processing window 170-230℃; it is recommended to set the heater 40-50℃ above the melting point; above 240℃ degradation accelerates, and molecular weight and viscosity drop rapidly
Lösung
①Melt temperature 170-230℃ adjusted according to the process; ②Sheet extrusion 170-230℃; ③Try not to exceed 240℃, over-temperature processes paired with 50ppm drying
Wichtigste Erkenntnis
PLA temperature window 170-230℃; the setting principle of 40-50℃ above the melting point balances plasticization and degradation prevention; after confirming effectiveness, fix the parameters and practices into the work instruction to prevent recurrence
PLA; melt temperature; 170-230℃; melting point; 40-50℃