Extrusion & Post 10 Aufrufe

SMMA Extrusion Processing

Problembeschreibung
SMMA extruded profiles, temperature 170-250℃ and cooling.
Ursachenanalyse
SMMA extrusion barrel temperature 170-250℃; screen filtration; water temperature at least 10℃ cooling; vacuum or flat plate calibration; surface quality.; during on-site troubleshooting, verify item by item according to this mechanism, avoiding blind machine adjustment based solely on experience
Lösung
①Extrusion temperature 170-250℃; ②screen configuration; ③cooling water temperature ≥10℃; ④calibration method; ⑤surface management.; after adjustment, continuously sample to verify the effect, and resume mass production only after confirming stability
Wichtigste Erkenntnis
Temperature and cooling of SMMA extrusion are the quality foundation; screen and calibration are equipment; management keeps consistency.; after confirming effectiveness, fix the parameters and practices into the work instruction to prevent recurrence