CPE Thermal Decomposition Above 190C
Problembeschreibung
Temperature exceeding 190C causes violent decomposition and blackening
Ursachenanalyse
Chlorine atoms are removed from the main chain, producing HCl
Lösung
Strictly control the processing temperature not to exceed 190C
Wichtigste Erkenntnis
Temperature is the red line for CPE processing