Material Analysis 10 Aufrufe

Low EAA elongation at break

Problembeschreibung
EAA product elongation at break <100% below the 200% requirement
Ursachenanalyse
EAA molecular weight too low, short chains with insufficient entanglement; excessive orientation causing extremely low transverse elongation; excessive crosslinking restricting chain slippage
Lösung
1) Select high molecular weight EAA to increase entanglement density; 2) Reduce orientation by lowering injection speed; 3) Control crosslinking degree to avoid excess
Wichtigste Erkenntnis
Low elongation at break is caused by low molecular weight and orientation; selecting high MW and reducing orientation is key
EAAelongation at breakmolecular weightorientation controlcrosslinking degree