EMA incompatible with lubricant
Problembeschreibung
After adding lubricant to EMA, lubricant oil spots exude on product surface
Ursachenanalyse
Poor compatibility between lubricant and EMA causes supersaturation exudation; lubricant molecular weight low with fast migration rate
Lösung
1) Select lubricant compatible with EMA; 2) Reduce lubricant dosage to 0.1-0.2wt% to avoid supersaturation; 3) Use internal lubricant instead of external lubricant
Wichtigste Erkenntnis
Lubricant incompatibility causes exudation; selecting compatible lubricant is key