Material Analysis 14 visualizações

EMA incompatible with lubricant

Fenómeno do problema
After adding lubricant to EMA, lubricant oil spots exude on product surface
Análise das causas
Poor compatibility between lubricant and EMA causes supersaturation exudation; lubricant molecular weight low with fast migration rate
Solução
1) Select lubricant compatible with EMA; 2) Reduce lubricant dosage to 0.1-0.2wt% to avoid supersaturation; 3) Use internal lubricant instead of external lubricant
Conclusão principal
Lubricant incompatibility causes exudation; selecting compatible lubricant is key
EMA lubricant exudation compatibility internal lubricant dosage control