Molding Process 6 Aufrufe

Poor EMA antistatic effect

Problembeschreibung
EMA product surface resistance >10¹²Ω with severe static electricity
Ursachenanalyse
Antistatic agent addition insufficient <0.1wt%; antistatic agent migration rate slow, not reaching the surface
Lösung
1) Increase antistatic agent to 0.3-0.5wt%; 2) Select antistatic agent with fast migration rate; 3) Surface coating with antistatic liquid for immediate effect
Wichtigste Erkenntnis
Poor antistatic effect is caused by insufficient addition; increasing antistatic agent is key