Extrusion & Post
9 Aufrufe
Excessive thermal shrinkage of EVA film
Problembeschreibung
EVA film thermal shrinkage at 80°C >12%, exceeding the 5% dimensional stability requirement
Ursachenanalyse
EVA extrusion orientation releases upon heating causing large shrinkage; EVA thermal expansion coefficient large; film cooling froze large amount of orientation stress
Lösung
1) Reduce extrusion draw ratio to reduce orientation freezing; 2) Film annealing treatment at 60-80°C to release orientation stress; 3) Add 5-10wt% rigid resin to reduce thermal shrinkage; 4) Biaxial stretching process to balance orientation
Wichtigste Erkenntnis
Film thermal shrinkage is caused by orientation freezing; reducing draw ratio and annealing treatment are key
War das hilfreich?
0 Personen fanden dies hilfreich
Vielen Dank für Ihr Feedback!