Material Analysis
10 Aufrufe
EVA processing temperature fluctuates
Problembeschreibung
During EVA processing, temperature fluctuates ±5-8°C, exceeding the ±2°C control accuracy
Ursachenanalyse
Improper PID parameters of the temperature control system; aging heater bands with uneven power; improper thermocouple position with measurement deviation
Lösung
1) Re-calibrate PID parameters; 2) Replace aging heater bands; 3) Adjust thermocouple position to the center of the melt pool
Wichtigste Erkenntnis
Temperature fluctuation is caused by an improper temperature control system; PID calibration and heater band replacement are key
War das hilfreich?
0 Personen fanden dies hilfreich
Vielen Dank für Ihr Feedback!