Processing Machinery
3 Aufrufe
Difficult EVOH Purging
Problembeschreibung
EVOH purging takes 2-3h, time-consuming and affecting changeover efficiency
Ursachenanalyse
EVOH has strong adhesion forming a firm adhesive layer on screw and barrel; EVOH has poor thermal stability, becoming sticky at high temperature and harder to remove
Lösung
1) Before purging, flush with high-viscosity PE to carry away EVOH residue; 2) Reduce purging temperature below EVOH softening point to reduce adhesion; 3) Use dedicated purging compound
Wichtigste Erkenntnis
Purging difficulty is caused by EVOH's strong adhesion; PE flushing and temperature reduction are key
War das hilfreich?
0 Personen fanden dies hilfreich