PVA injection cold slug marks

Problembeschreibung
PVA injection molded product shows cold slug marks near the gate
Ursachenanalyse
Nozzle temperature on the low side causes residual material from the previous shot to cool and solidify in the nozzle; cold slug well design insufficient to accommodate the cold slug; injection pressure insufficient
Lösung
1) Raise nozzle temperature to 140-200°C; 2) Mold design with a sufficiently large cold slug well; 3) Ensure fresh melt at the nozzle front before each injection; 4) Increase injection pressure to push the cold slug through the gate
Wichtigste Erkenntnis
Cold slug marks are caused by solidified residual material in the nozzle; raising nozzle temperature and cold slug well design are the key