Improper draft angle design, product sticking to mold or deforming
Problembeschreibung
Improper draft angle design, product sticking to mold or deforming
Ursachenanalyse
Draft angle <0.5°, demolding difficult
Deep-cavity products have insufficient draft angle
Textured surfaces require increased draft angle
Cellulose acetate butyrate shrinkage rate 0.4-0.6% needs to be matched with the draft angle
Core and cavity draft angles inconsistent
Lösung
Draft angle ≥1° for conventional products
Deep-cavity products draft angle 1.5-3°
Textured surface increase 0.5° per 0.01mm depth
Design the draft angle according to the 0.4-0.6% shrinkage rate
Ensure core and cavity draft angles are consistent
Wichtigste Erkenntnis
Draft angle needs to be designed according to shrinkage rate and product depth