Material Drying 3 Aufrufe

Mismatch of testing methods and standards leads to wrong quality judgment

Problembeschreibung
Mismatch of testing methods and standards leads to wrong quality judgment
Ursachenanalyse
Testing conditions do not consider the moisture absorption state of cellulose acetate butyrate Impact test conducted in dry state, results low Dimensional inspection not performed after conditioning Visual inspection standards unclear Mechanical property test conditions do not match the use environment
Lösung
Products need conditioning to equilibrium moisture content before testing Impact test conducted in wet state (moisture 1.5-2.5%) Dimensional inspection performed after conditioning Establish clear appearance inspection standards Test conditions match the use environment
Wichtigste Erkenntnis
Testing needs to be conducted under correct moisture content conditions
quality inspectionmoisture contentconditioningPA testing