Injection Molding 4 Aufrufe

Abnormal pressure curve reflects process or equipment problems

Problembeschreibung
Abnormal pressure curve reflects process or equipment problems
Ursachenanalyse
Pressure curve peak too high, clamping force insufficient, flash Pressure curve low, injection pressure insufficient, short shots Large pressure curve fluctuation, hydraulic system unstable Holding pressure section pressure decays too fast, gate freezes prematurely Pressure sensor failure, inaccurate data
Lösung
If the pressure peak is too high, reduce injection speed or increase clamping force If the pressure is low, increase injection pressure Stabilize the hydraulic system Extend gate freezing time to prevent holding pressure decay Calibrate the pressure sensor
Wichtigste Erkenntnis
Pressure monitoring requires stable hydraulics and calibrated sensors
pressure monitoringhydraulic systemsensorgate freezing